Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 95
Filtrar
1.
Insights Imaging ; 13(1): 83, 2022 May 04.
Artigo em Inglês | MEDLINE | ID: mdl-35507196

RESUMO

The deployment of electronic patient portals increasingly allows patients throughout Europe to consult and share their radiology reports and images securely and timely online. Technical solutions and rules for releasing reports and images on patient portals may differ among institutions, regions and countries, and radiologists should therefore be familiar with the criteria by which reports and images are made available to their patients. Radiologists may also be solicited by patients who wish to discuss complex or critical imaging findings directly with the imaging expert who is responsible for the diagnosis. This emphasises the importance of radiologists' communication skills as well as appropriate and efficient communication pathways and methods including electronic tools. Radiologists may also have to think about adapting reports as their final product in order to enable both referrers and patients to understand imaging findings. Actionable reports for a medical audience require structured, organ-specific terms and quantitative information, whereas patient-friendly summaries should preferably be based on consumer health language and include explanatory multimedia support or hyperlinks. Owing to the cultural and linguistic diversity in Europe dedicated solutions will require close collaboration between radiologists, patient representatives and software developers; software tools using artificial intelligence and natural language processing could potentially be useful in this context. By engaging actively in the challenges that are associated with increased communication with their patients, radiologists will not only have the opportunity to contribute to patient-centred care, but also to enhance the clinical relevance and the visibility of their profession.

3.
Medicine (Baltimore) ; 98(7): e14450, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30762757

RESUMO

To compare 2 incompatible generations of iterative reconstructions from the same raw dataset based on automatic emphysema quantification and noise reduction: a hybrid algorithm called sinogram affirmed iterative reconstruction (SAFIRE) versus a model-based algorithm called advanced modeled iterative reconstruction (ADMIRE).Raw datasets of 40 non-contrast thoracic computed tomography scanners obtained from a single acquisition on a SOMATOM Definition Flash unit (Siemens Healthcare, Forchheim) were reconstructed with 3 levels of SAFIRE and ADMIRE algorithms resulting in a total of 240 datasets. Emphysema index (EI) and image noise were compared using repeated analysis of variance (ANOVA) analysis with a P value <.05 considered statistically significant.EI and image noise were stable between both generations of IR when reconstructed with the same level (P ≥0.31 and P ≥0.06, respectively).SAFIRE and ADMIRE perform equally in terms of emphysema quantification and noise reduction.


Assuntos
Algoritmos , Conjuntos de Dados como Assunto/estatística & dados numéricos , Enfisema Pulmonar/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/estatística & dados numéricos , Análise de Variância , Humanos , Razão Sinal-Ruído
4.
J Mater Chem B ; 7(6): 927-939, 2019 02 14.
Artigo em Inglês | MEDLINE | ID: mdl-32255098

RESUMO

The purpose of this study was to develop micron-sized droplet emulsions able to increase the heat deposition of high intensity focused ultrasound (HIFU), aiming to accelerate the tumour ablation in highly perfused organs with reduced side effects. The investigated droplets consisted of a perfluorooctyl bromide (PFOB) core coated with a biocompatible fluorinated surfactant called F-TAC. The novelty of this work relies on the use, for this application, of a high boiling point perfluorocarbon core (142 °C), combined with an in-house fluorinated surfactant to formulate the emulsion, yielding quasi-reversible strong interactions between the HIFU beam and the droplets. In order to fine-tune the emulsion size, surfactants with different hydrophobic/hydrophilic ratios were screened. Different concentrations of PFOB droplets were homogeneously embedded in two different MRI compatible materials, exhibiting either ultrasound (US) absorbing or non-absorbing properties. For the US absorbing TMM, the speed of sound at each droplet concentration was also assessed. These TMM were sonicated by 1 MHz HIFU with acoustical power of 94 W at two different duty cycles. The temperature elevation was monitored accurately by MRI proton shift resonance frequency in near real-time. The presence of sono-sensitive droplets induced a significant increase of the HIFU thermal effect that persisted under repeated sonication of the same locus. Optimal enhancement was observed at the lowest concentration tested (0.1%) with an additional temperature rise at the focal point of approximately 4 °C per applied kJ of acoustic energy corresponding to one order of magnitude augmentation of the thermal dose. Furthermore, no deformation of the heating pattern pre- or post-focal was observed.


Assuntos
Fluorocarbonos/química , Tensoativos/química , Materiais Biocompatíveis/química , Meios de Contraste/química , Ablação por Ultrassom Focalizado de Alta Intensidade/métodos , Humanos , Interações Hidrofóbicas e Hidrofílicas , Hipertermia Induzida , Imageamento por Ressonância Magnética , Neoplasias/terapia , Tamanho da Partícula , Temperatura , Ultrassonografia
5.
IEEE Trans Biomed Eng ; 66(8): 2182-2191, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-30530308

RESUMO

OBJECTIVE: High intensity focused ultrasound (HIFU) treatment in the abdominal cavity is challenging due to the respiratory motion. In the self-scanning HIFU ablation method, the focal spot is kept static and the heating pattern is obtained through natural tissue motion. This paper describes a novel approach for modulating the HIFU power during self-scanning in order to compensate for the effect of tissue motion on thermal buildup. METHODS: The therapy, using hybrid ultrasound (US)/magnetic resonance (MR) imaging, consists of detecting and tracking speckle on US images in order to predict the next tissue position, and modulating the HIFU power according to the tissue speed in order to obtain a rectilinear pattern of uniform temperature elevation. Experiments were conducted on ex vivo tissue subjected to a breathing-like motion generated by an MR-compatible robot and sonicated by a phased array HIFU transducer. RESULTS: US and MR data were free from interferences. For both periodic and non-periodic motion, MR temperature maps showed a substantial improvement in the uniformity of the temperature elevation by using acoustic power modulation. CONCLUSION: The presented method does not require a learning stage and enables a duty cycle close to 100%, higher average acoustic intensity and avoidance of side lobe effects versus performing HIFU beam steering to compensate tissue motion. SIGNIFICANCE: To our knowledge, the proposed method provides the first experimental validation of the self-scanning HIFU ablation paradigm via a real-time hybrid MRI/US imaging, opening the path toward self-scanning in vivo therapies.


Assuntos
Ablação por Ultrassom Focalizado de Alta Intensidade/métodos , Imageamento por Ressonância Magnética/métodos , Movimento/fisiologia , Ultrassonografia/métodos , Algoritmos , Animais , Interpretação de Imagem Assistida por Computador/métodos , Modelos Biológicos , Músculo Esquelético/diagnóstico por imagem , Termometria , Perus
6.
Eur Radiol ; 28(11): 4810-4817, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-29789913

RESUMO

OBJECTIVES: To evaluate the safety and efficacy of ethylene vinyl alcohol copolymer (EVOH) injection for selective occlusion of portal branches considered at risk for non-target embolisation during preoperative portal vein embolisation (PVE). METHODS: Twenty-nine patients (mean age, 57 ± 17 years) submitted to PVE with n-butyl-cyanoacrylate (NBCA) and additional EVOH for selected portal branches were retrospectively analysed. Indications for the use of EVOH and the selected portal branches were evaluated. Degree of hypertrophy of the future liver remnant (FLR) and kinetic growth were assessed by CT volumetry performed before and 3-6 weeks after PVE. Clinical outcome and histopathological analysis of portal veins occluded with EVOH were reviewed. RESULTS: EVOH was indicated intraoperatively for embolisation of selected portal branches that the operator reported at risk to provoke non-target embolisation with NBCA. Indications for the use of EVOH were embolisation of segment IV (n = 21), embolisation of segmental portal branches with early bifurcation (n = 7) and PVE in a 1-year-old girl with cystic hamartomas. All targeted portal branches were successfully embolised. There were no cases with non-target embolisation by EVOH. The degree of hypertrophy of the FLR was 14.3 ± 8.1% and the kinetic growth rate was 2.7 ± 1.8% per week. CONCLUSION: EVOH is safe and effective for embolisation of selected portal vein branches considered at risk for non-target embolisation. KEY POINTS: • EVOH is another effective liquid embolic agent for preoperative PVE. • EVOH is relatively simple to handle with a minimal risk of non-target embolisation. • During PVE, some portal branches considered complicated to occlude with NBCA may be efficiently embolised with EVOH.


Assuntos
Embolização Terapêutica/métodos , Embucrilato/administração & dosagem , Hepatectomia , Neoplasias Hepáticas/irrigação sanguínea , Polivinil/administração & dosagem , Cuidados Pré-Operatórios/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Injeções Intravenosas , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/terapia , Masculino , Pessoa de Meia-Idade , Veia Porta , Estudos Retrospectivos , Tomografia Computadorizada Espiral , Adulto Jovem
7.
Br J Radiol ; 91(1088): 20170443, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29762055

RESUMO

OBJECTIVE: To compare radiation dose and image quality of thoracoabdominal scans obtained with a high-pitch protocol (pitch 3.2) and iterative reconstruction (Sinogram Affirmed Iterative Reconstruction) in comparison to standard pitch reconstructed with filtered back projection (FBP) using dual source CT. METHODS: 114 CT scans (Somatom Definition Flash, Siemens Healthineers, Erlangen, Germany), 39 thoracic scans, 54 thoracoabdominal scans and 21 abdominal scans were performed. Analysis of three protocols was undertaken; pitch of 1 reconstructed with FBP, pitch of 3.2 reconstructed with SAFIRE, pitch of 3.2 with stellar detectors reconstructed with SAFIRE. Objective and subjective image analysis were performed. Dose differences of the protocols used were compared. RESULTS: Dose was reduced when comparing scans with a pitch of 1 reconstructed with FBP to high-pitch scans with a pitch of 3.2 reconstructed with SAFIRE with a reduction of volume CT dose index of 75% for thoracic scans, 64% for thoracoabdominal scans and 67% for abdominal scans. There was a further reduction after the implementation of stellar detectors reflected in a reduction of 36% of the dose-length product for thoracic scans. This was not at the detriment of image quality, contrast-to-noise ratio, signal-to-noise ratio and the qualitative image analysis revealed a superior image quality in the high-pitch protocols. CONCLUSION: The combination of a high pitch protocol with iterative reconstruction allows significant dose reduction in routine chest and abdominal scans whilst maintaining or improving diagnostic image quality, with a further reduction in thoracic scans with stellar detectors. Advances in knowledge: High pitch imaging with iterative reconstruction is a tool that can be used to reduce dose without sacrificing image quality.


Assuntos
Abdome/diagnóstico por imagem , Processamento de Imagem Assistida por Computador , Doses de Radiação , Tórax/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Melhoria de Qualidade , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/normas
8.
Eur Respir J ; 51(5)2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29650558

RESUMO

The diagnosis of pneumonia is challenging. Our objective was to assess whether low-dose computed tomography (LDCT) modified the probability of diagnosing pneumonia in elderly patients.We prospectively included patients aged over 65 years with a suspicion of pneumonia treated with antimicrobial therapy (AT). All patients had a chest radiograph and LDCT within 72 h of inclusion. The treating clinician assessed the probability of pneumonia before and after the LDCT scan using a Likert scale. An adjudication committee retrospectively rated the probability of pneumonia and was considered as the reference for diagnosis. The main outcome was the difference in the clinician's pneumonia probability estimates before and after LDCT and the proportion of modified diagnoses which matched the reference diagnosis (the net reclassification improvement (NRI)).A total of 200 patients with a median age of 84 years were included. After LDCT, the estimated probability of pneumonia changed in 90 patients (45%), of which 60 (30%) were downgraded and 30 (15%) were upgraded. The NRI was 8% (NRI event (-6%) + NRI non-event (14%)).LDCT modified the estimated probability of pneumonia in a substantial proportion of patients. It mostly helped to exclude a diagnosis of pneumonia and hence to reduce unnecessary AT.


Assuntos
Pneumonia/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Idoso , Idoso de 80 Anos ou mais , Comorbidade , Reações Falso-Positivas , Feminino , Humanos , Masculino , Probabilidade , Estudos Prospectivos , Curva ROC , Suíça
9.
Magn Reson Med ; 79(5): 2511-2523, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-28944490

RESUMO

PURPOSE: Treatments using high-intensity focused ultrasound (HIFU) in the abdominal region remain challenging as a result of respiratory organ motion. A novel method is described here to achieve 3D motion-compensated ultrasound (US) MR-guided HIFU therapy using simultaneous ultrasound and MRI. METHODS: A truly hybrid US-MR-guided HIFU method was used to plan and control the treatment. Two-dimensional ultrasound was used in real time to enable tracking of the motion in the coronal plane, whereas an MR pencil-beam navigator was used to detect anterior-posterior motion. Prospective motion compensation of proton resonance frequency shift (PRFS) thermometry and HIFU electronic beam steering were achieved. RESULTS: The 3D prospective motion-corrected PRFS temperature maps showed reduced intrascan ghosting artifacts, a high signal-to-noise ratio, and low geometric distortion. The k-space data yielded a consistent temperature-dependent PRFS effect, matching the gold standard thermometry within approximately 1°C. The maximum in-plane temperature elevation ex vivo was improved by a factor of 2. Baseline thermometry acquired in volunteers indicated reduction of residual motion, together with an accuracy/precision of near-harmonic referenceless PRFS thermometry on the order of 0.5/1.0°C. CONCLUSIONS: Hybrid US-MR-guided HIFU ablation with 3D motion compensation was demonstrated ex vivo together with a stable referenceless PRFS thermometry baseline in healthy volunteer liver acquisitions. Magn Reson Med 79:2511-2523, 2018. © 2017 International Society for Magnetic Resonance in Medicine.


Assuntos
Ablação por Ultrassom Focalizado de Alta Intensidade/métodos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Cirurgia Assistida por Computador/métodos , Adulto , Algoritmos , Animais , Bovinos , Feminino , Humanos , Fígado/diagnóstico por imagem , Fígado/cirurgia , Masculino , Termometria/métodos
10.
Eur Radiol ; 28(3): 1054-1065, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28887589

RESUMO

PURPOSE: This work provides detailed estimates of the foetal dose from diagnostic CT imaging of pregnant patients to enable the assessment of the diagnostic benefits considering the associated radiation risks. MATERIALS AND METHODS: To produce realistic biological and physical representations of pregnant patients and the embedded foetus, we developed a methodology for construction of patient-specific voxel-based computational phantoms based on existing standardised hybrid computational pregnant female phantoms. We estimated the maternal absorbed dose and foetal organ dose for 30 pregnant patients referred to the emergency unit of Geneva University Hospital for abdominal CT scans. RESULTS: The effective dose to the mother varied from 1.1 mSv to 2.0 mSv with an average of 1.6 mSv, while commercial dose-tracking software reported an average effective dose of 1.9 mSv (range 1.7-2.3 mSv). The foetal dose normalised to CTDIvol varies between 0.85 and 1.63 with an average of 1.17. CONCLUSION: The methodology for construction of personalised computational models can be exploited to estimate the patient-specific radiation dose from CT imaging procedures. Likewise, the dosimetric data can be used for assessment of the radiation risks to pregnant patients and the foetus from various CT scanning protocols, thus guiding the decision-making process. KEY POINTS: • In CT examinations, the absorbed dose is non-uniformly distributed within foetal organs. • This work reports, for the first time, estimates of foetal organ-level dose. • The foetal brain and skeleton doses present significant correlation with gestational age. • The conceptus dose normalised to CTDI vol varies between 0.85 and 1.63. • The developed methodology is adequate for patient-specific CT radiation dosimetry.


Assuntos
Feto/efeitos da radiação , Complicações na Gravidez/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Simulação por Computador , Feminino , Idade Gestacional , Humanos , Masculino , Método de Monte Carlo , Imagens de Fantasmas , Gravidez , Doses de Radiação , Radiografia Abdominal/métodos , Radiometria/métodos , Estudos Retrospectivos , Medição de Risco
11.
Eur Radiol ; 28(2): 651-663, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28812148

RESUMO

PURPOSE: To determine the diagnostic performance of FDG-PET/MRI with diffusion-weighted imaging (FDG-PET/DWIMRI) for detection and local staging of head and neck squamous cell carcinoma (HNSCC) after radio(chemo)therapy. MATERIALS AND METHODS: This was a prospective study that included 74 consecutive patients with previous radio(chemo)therapy for HNSCC and in whom tumour recurrence or radiation-induced complications were suspected clinically. The patients underwent hybrid PET/MRI examinations with morphological MRI, DWI and FDG-PET. Experienced readers blinded to clinical/histopathological data evaluated images according to established diagnostic criteria taking into account the complementarity of multiparametric information. The standard of reference was histopathology with whole-organ sections and follow-up ≥24 months. Statistical analysis considered data clustering. RESULTS: The proof of diagnosis was histology in 46/74 (62.2%) patients and follow-up (mean ± SD = 34 ± 8 months) in 28/74 (37.8%). Thirty-eight patients had 43 HNSCCs and 46 patients (10 with and 36 without tumours) had 62 benign lesions/complications. Sensitivity, specificity, and positive and negative predictive value of PET/DWIMRI were 97.4%, 91.7%, 92.5% and 97.1% per patient, and 93.0%, 93.5%, 90.9%, and 95.1% per lesion, respectively. Agreement between imaging-based and pathological T-stage was excellent (kappa = 0.84, p < 0.001). CONCLUSION: FDG-PET/DWIMRI yields excellent results for detection and T-classification of HNSCC after radio(chemo)therapy. KEY POINTS: • FDG-PET/DWIMRI yields excellent results for the detection of post-radio(chemo)therapy HNSCC recurrence. • Prospective one-centre study showed excellent agreement between imaging-based and pathological T-stage. • 97.5% of positive concordant MRI, DWI and FDG-PET results correspond to recurrence. • 87% of discordant MRI, DWI and FDG-PET results correspond to benign lesions. • Multiparametric FDG-PET/DWIMRI facilitates planning of salvage surgery in the irradiated neck.


Assuntos
Carcinoma de Células Escamosas/diagnóstico , Imagem de Difusão por Ressonância Magnética/métodos , Fluordesoxiglucose F18/farmacologia , Neoplasias de Cabeça e Pescoço/diagnóstico , Recidiva Local de Neoplasia/diagnóstico , Tomografia por Emissão de Pósitrons/métodos , Adulto , Idoso , Carcinoma de Células Escamosas/terapia , Quimiorradioterapia , Feminino , Neoplasias de Cabeça e Pescoço/terapia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Compostos Radiofarmacêuticos/farmacologia , Carcinoma de Células Escamosas de Cabeça e Pescoço
12.
Radiol Med ; 122(10): 731-742, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28643295

RESUMO

OBJECTIVE: To compare two fat suppression techniques used for 3D T1-weighted sequence in breast MRI (magnetic resonance imaging), namely Dixon versus spectral fat saturation (fat sat). MATERIALS AND METHODS: All breast MRI examinations performed in a Philips 3 T unit between March 2013 and October 2015 including either a Dixon or a fat sat sequence were retrospectively analyzed. The examinations were subjectively evaluated by two independent experienced readers in a scale of 5 for overall quality of fat suppression, homogeneity of fat suppression, definition of anatomic structures and focal lesions, diagnostic confidence for axillary and internal mammary regions and the presence of artifacts, 1 corresponding to excellent and 5 to non-diagnostic quality. Contrast-to-noise-ratio (CNR) measurements for muscle and focal lesions were also performed. RESULTS: Overall 161 women (mean age 51.6 ± 12.0 years) underwent 189 MR examinations, 113 with the fat saturation and 76 with the Dixon sequence. Interobserver variability was good (kappa = 0.757). In all subjectively evaluated parameters, the Dixon sequence was superior to the fat sat (p < 0.05). Mean values of CNR for muscle and focal lesions were 9.98 (±4.2), 17.9 (±7.53) for the fat sat and 18.3 (±10.4) and 29.3 (±14.1) for the Dixon sequence, respectively (p < 0.001). CONCLUSION: 3D T1 Dixon sequence is superior to fat sat for dedicated breast MRI at 3 T, in terms of efficiency of fat suppression and image quality with the added advantage of optimal exploration of the axillary areas.


Assuntos
Tecido Adiposo/diagnóstico por imagem , Neoplasias da Mama/diagnóstico por imagem , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Artefatos , Meios de Contraste , Feminino , Humanos , Pessoa de Meia-Idade , Estudos Retrospectivos
13.
J Clin Imaging Sci ; 7: 9, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28299237

RESUMO

Asymptomatic spontaneous nephrocutaneous fistula is a rare and severe complication of chronic urolithiasis. We report a case of 56-year-old woman with a nephrocutaneous fistula (NFC) which developed from a superinfected urinoma following calyceal rupture due to an obstructing calculus in the left ureter. The patient was clinically asymptomatic and came to the emergency department for a painless left flank fluctuating mass. This urinoma was superinfected, with a delayed development of renal abscesses and perirenal phlegmon found on contrast-enhanced uro-computed tomography (CT), responsible for left renal vein thrombophlebitis and left psoas abscess. Thereafter, a 99 mTc dimercaptosuccinic acid (DMSA) scintigraphy revealed a nonfunctional left kidney, leading to the decision of left nephrectomy. Chronic urolithiasis complications are rare and only few cases are reported in medical literature. A systematic medical approach helped selecting the best imaging modality to help diagnosis and treatment. Indeed, uro-CT scan and renal scintigraphy with 99 mTc-DMSA are the most sensitive imaging modalities to investigate morphological and functional urinary tract consequences of NFC, secondary to chronic urolithiasis.

14.
Eur Radiol ; 27(8): 3300-3309, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28083698

RESUMO

OBJECTIVES: To determine if radiation dose delivered by contrast-enhanced CT (CECT) for acute abdominal pain can be reduced to the dose administered in abdominal radiography (<2.5 mSv) using low-dose CT (LDCT) with iterative reconstruction algorithms. METHODS: One hundred and fifty-one consecutive patients requiring CECT for acute abdominal pain were included, and their body mass index (BMI) was calculated. CECT was immediately followed by LDCT. LDCT series was processed using 1) 40% iterative reconstruction algorithm blended with filtered back projection (LDCT-IR-FBP) and 2) model-based iterative reconstruction algorithm (LDCT-MBIR). LDCT-IR-FBP and LDCT-MBIR images were reviewed independently by two board-certified radiologists (Raters 1 and 2). RESULTS: Abdominal pathology was revealed on CECT in 120 (79%) patients. In those with BMI <30, accuracies for correct diagnosis by Rater 1 with LDCT-IR-FBP and LDCT-MBIR, when compared to CECT, were 95.4% (104/109) and 99% (108/109), respectively, and 92.7% (101/109) and 100% (109/109) for Rater 2. In patients with BMI ≥30, accuracies with LDCT-IR-FBP and LDCT-MBIR were 88.1% (37/42) and 90.5% (38/42) for Rater 1 and 78.6% (33/42) and 92.9% (39/42) for Rater 2. CONCLUSIONS: The radiation dose delivered by CT to non-obese patients with acute abdominal pain can be safely reduced to levels close to standard radiography using LDCT-MBIR. KEY POINTS: • LDCT-MBIR (<2.5 mSv) can be used to assess acute abdominal pain. • LDCT-MBIR (<2.5 mSv) cannot safely assess acute abdominal pain in obese patients. • LDCT-IR-FBP (<2.5 mSv) cannot safely assess patients with acute abdominal pain.


Assuntos
Abdome Agudo/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Abdome Agudo/etiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Índice de Massa Corporal , Emergências , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Radiografia Abdominal/métodos , Cintilografia , Tomografia Computadorizada por Raios X/métodos , Adulto Jovem
15.
Eur Radiol ; 27(7): 2950-2956, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27847999

RESUMO

OBJECTIVES: To prospectively evaluate the impact of iterative reconstruction (IR) algorithms on pulmonary emphysema assessment as compared to filtered back projection (FBP). METHODS: One hundred ten unenhanced chest CT examinations were obtained on two different scanners. Image reconstructions from a single acquisition were done with different levels of IR and compared with FBP on the basis of the emphysema index (EI), lung volume and voxel densities. Objective emphysema assessment was performed with 3D software provided by each manufacturer. Subjective assessment of emphysema was performed as a blinded evaluation. Quantitative and subjective values were compared using repeated ANOVA analysis, Bland-Altman analysis and Kendall's coefficient of concordance (W). RESULTS: Lung volumes are stable on both units, throughout all IR levels (P ≥ 0.057). EI significantly decreases on both units with the use of any level of IR (P < 0.001). The highest levels of IR are responsible for a decrease of 33-36 % of EI. Significant differences in minimal lung density are found between the different algorithms (P < 0.003). Intra- and inter-reader concordance for emphysema characterisation is generally good (W ≥ 0.77 and W ≥ 0.86, respectively). CONCLUSIONS: Both commercially available IR algorithms used in this study significantly changed EI but did not alter visual assessment compared to standard FBP reconstruction at identical radiation exposure. KEY POINTS: • Objective quantification of pulmonary emphysema is sensitive to iterative reconstructions • Subjective evaluation of pulmonary emphysema is not influenced by iterative reconstructions • Consistency in reconstruction algorithms is of paramount importance for pulmonary emphysema monitoring.


Assuntos
Algoritmos , Enfisema Pulmonar/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Software
16.
Abdom Radiol (NY) ; 42(2): 460-467, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-27604894

RESUMO

PURPOSE: To evaluate the prognostic value of abdominal computed tomography (CT) in patients with alcoholic hepatitis (AH). METHODS: This ancillary study was based on data collected during a previous randomized controlled trial in patients with AH. Clinical response was defined as the improvement of the baseline MELD score ≥3 points at 3 months. All patients underwent contrast-enhanced CT of the abdomen. The following parameters were measured: (1) liver density, spleen density, and liver-to-spleen density ratio; (2) liver-to-body weight (LBW) ratio; and (3) subcutaneous fat, visceral fat, and muscular content. Improvers and non-improvers were compared with univariate, multivariate, and ROC analyses. Results were compared with a validation cohort of patients. RESULTS: Fifty-eight patients (mean age, 56 years) were analyzed, including 34 (59 %) improvers. On multivariate analysis, LBW ratio (OR = 3.73; 95 % CI, 1.65-8.46; p = 0.002) and subcutaneous fat (OR = 1.01; 95 % CI, 1.00-1.02; p = 0.022) were associated with clinical response, with AUROC curves of 0.78 ± 0.06 (p < 0.001) and 0.66 ± 0.07 (p = 0.043), respectively. LBW ≥2.4 % predicted response with 88 % sensitivity and 63 % specificity. In the validation cohort (n = 42, 64 % improvers), the same cut-off value predicted response with 93 % sensitivity and 60 % specificity. CONCLUSIONS: In patients suffering from AH, the liver volume appears to be a major positive prognostic factor.


Assuntos
Hepatite Alcoólica/diagnóstico por imagem , Hepatite Alcoólica/patologia , Composição Corporal , Meios de Contraste , Feminino , Humanos , Fígado/diagnóstico por imagem , Fígado/patologia , Masculino , Pessoa de Meia-Idade , Tamanho do Órgão , Prognóstico , Fatores de Risco , Sensibilidade e Especificidade , Baço/diagnóstico por imagem , Baço/patologia , Tomografia Computadorizada por Raios X
17.
World J Radiol ; 8(7): 693-9, 2016 Jul 28.
Artigo em Inglês | MEDLINE | ID: mdl-27551339

RESUMO

AIM: To evaluate the image quality of hepatic multidetector computed tomography (MDCT) with dynamic contrast enhancement. METHODS: It uses iodixanol 270 mg/mL (Visipaque 270) and 80 kVp acquisitions reconstructed with sinogram affirmed iterative reconstruction (SAFIRE(®)) in comparison with a standard MDCT protocol. Fifty-three consecutive patients with known or suspected hepatocellular carcinoma underwent 55 CT examinations, with two different four-phase CT protocols. The first group of 30 patients underwent a standard 120 kVp acquisition after injection of Iohexol 350 mg/mL (Accupaque 350(®)) and reconstructed with filtered back projection. The second group of 25 patients underwent a dual-energy CT at 80-140 kVp with iodixanol 270. The 80 kVp component of the second group was reconstructed iteratively (SAFIRE(®)-Siemens). All hyperdense and hypodense hepatic lesions ≥ 5 mm were identified with both protocols. Aorta and portal vessels/liver parenchyma contrast to noise ratio (CNR) in arterial phase, hypervascular lesion/liver parenchyma CNR in arterial phase, hypodense lesion/liver parenchyma CNR in portal and late phase were calculated in both groups. RESULTS: Aorta/liver and focal lesions altogether/liver CNR were higher for the second protocol (P = 0.0078 and 0.0346). Hypervascular lesions/liver CNR was not statistically different (P = 0.86). Hypodense lesion/liver CNR in the portal phase was significantly higher for the second group (P = 0.0107). Hypodense lesion/liver CNR in the late phase was the same for both groups (P = 0.9926). CONCLUSION: MDCT imaging with 80 kVp with iterative reconstruction and iodixanol 270 yields equal or even better image quality.

18.
J Cardiovasc Comput Tomogr ; 10(5): 407-13, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27451049

RESUMO

OBJECTIVES: To study the image quality of ECG-gated-computed tomography (CT) acquisition with a high-pitch CT imaging for the exploration of both the aorta and coronary arteries. METHODS: Eighty-four patients underwent high-pitch ECG-gated aortic CT without ß-blockers with iterative reconstruction algorithms. Contrast-to-noise ratio (CNR) between vessels and adjacent perivascular fat tissue were calculated on the aorta and the coronary arteries. Dose-length-products (DLP) were recorded. Two blinded readers graded image quality of the aorta and the coronary arteries on a 3-point scale. Coronary artery stenoses were compared with coronary angiograms in 24 patients. Kappa values were calculated. RESULTS: High-pitch acquisition resulted in a mean DLP of 234 ± 93 mGy cm(4.2 mSv) for an acquisition of the entire aorta, (mean 73 ± 16 bpm). CNR for ascending aorta was 10.6 ± 4 and CNR for coronary arteries was 9.85 ± 4.1. Image quality was excellent in 79/84 patients (94%), and excellent or moderate but diagnostic in 1087/1127 coronary artery segments (96%). 74 significant stenoses were observed, and 38/40 significant stenoses were confirmed by coronary angiography (K = 0.91, Sensitivity = 0.97, Specificity = 0.98). CONCLUSION: High-pitch ECG-gated aortic CT with iterative reconstructions allows an accurate exploration of both aorta and coronary arteries during the same acquisition, with limited dose deposition, despite the lack of ß-blockers and relatively high heart rate. Radiologists need to be aware of the necessity to analyze and report coronary artery disease in aortic examination.


Assuntos
Aorta/diagnóstico por imagem , Doenças da Aorta/diagnóstico por imagem , Valva Aórtica/diagnóstico por imagem , Aortografia/métodos , Técnicas de Imagem de Sincronização Cardíaca , Angiografia por Tomografia Computadorizada , Angiografia Coronária/métodos , Estenose Coronária/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Eletrocardiografia , Tomografia Computadorizada Multidetectores , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Aorta/fisiopatologia , Doenças da Aorta/fisiopatologia , Valva Aórtica/fisiopatologia , Artefatos , Meios de Contraste/administração & dosagem , Estenose Coronária/fisiopatologia , Vasos Coronários/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Valor Preditivo dos Testes , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador , Reprodutibilidade dos Testes , Estudos Retrospectivos , Razão Sinal-Ruído , Adulto Jovem
19.
BMC Med Imaging ; 16: 3, 2016 Jan 13.
Artigo em Inglês | MEDLINE | ID: mdl-26762344

RESUMO

BACKGROUND: The recent implementation of the dual energy technology on CT-scanners has opened new perspectives in tissue and material characterization. This study aims to evaluate whether dual energy CT can be used to assess the concentration of cocaine of intra-intestinal illegal packets. METHODS: The study was approved by the institutional review board of our institution (CER 13_027_R). From November 2010 to May 2013, all consecutive conveyors in whom a low-dose abdominal CT (LDCT) revealed the presence of illegal intra-corporeal drug packets underwent a dual energy CT series (gemstone spectral imaging) targeted on one container. The mean radiological density (HU) of these packets was measured on the LDCT series, and on the monochromatic dual energy series, at 40 and 140 keV. The difference between the HU at 40 and 140 keV was reported as ∆HU. The effective atomic number Z(eff) was also measured on the monochromatic series. A chemical analysis was performed after expulsion to select cocaine containing packets, and to determine their cocaine concentrations. A correlation analysis was performed between HU, ∆HU and Z(eff), with regard to the percentage of cocaine. RESULTS: Fifty-four cocaine conveyors were included. The mean cocaine content of the packets was 36.8% (range 11.2-80, SD 15.4), the mean radiologic density 105 HU, the mean Z(eff) 8.7 and the mean ∆HU 163. The cocaine content was correlated with the ∆HU (0.57, p < 0.001), with the Z(eff) (r = 0.56, p < 0.001) but not with radiologic density (r = 0.25, p = 0.064). ∆HU >200 was 0.9 (9 of 10) sensitive and 0.82 (36 of 44) specific to predict a cocaine concentration higher than 50%. CONCLUSION: Measuring ∆HU or Z(eff) on dual energy monochromatic CT series can be used to detect ingested packets with cocaine concentration >50%.


Assuntos
Cocaína/análise , Corpos Estranhos/diagnóstico por imagem , Intestinos/diagnóstico por imagem , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Estudos Transversais , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
20.
Eur Radiol ; 26(7): 2297-307, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26477029

RESUMO

OBJECTIVE: To evaluate the performance of 18F-fluorodeoxyglucose (FDG) positron emission tomography magnetic resonance imaging (PET/MR) for preoperative breast cancer staging. METHODS: Preoperative PET/MR exams of 58 consecutive women with breast cancer were retrospectively reviewed. Histology and mean follow-up of 26 months served as gold standard. Four experienced readers evaluated primary lesions, lymph nodes and distant metastases with contrast-enhanced MRI, qualitative/quantitative PET, and combined PET/MR. ROC curves were calculated for all modalities and their combinations. RESULTS: The study included 101 breast lesions (83 malignant, 18 benign) and 198 lymph node groups, (34 malignant, 164 benign). Two patients had distant metastases. Areas under the curve (AUC) for breast cancer were 0.9558, 0.8347 and 0.8855 with MRI, and with qualitative and quantitative PET/MR, respectively (p = 0.066). Sensitivity for primary cancers with MRI and quantitative PET/MR was 100 % and 77 % (p = 0.004), and for lymph nodes 88 % and 79 % (p = 0.25), respectively. Specificity for MRI and PET/MR for primary cancers was 67 % and 100 % (p = 0.03) and for lymph nodes 98 % and 100 % (p = 0.25). CONCLUSIONS: In breast cancer patients, MRI alone has the highest sensitivity for primary tumours. For nodal metastases, both MRI and PET/MR are highly specific. KEY POINTS: • MRI alone and PET/MR have a similar overall diagnostic performance. • MRI alone has a higher sensitivity than PET/MR for local tumour assessment. • Both MRI and PET/MR have a limited sensitivity for nodal metastases. • Positive lymph nodes on MRI or PET/MR do not require presurgical biopsy.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Fluordesoxiglucose F18 , Imageamento por Ressonância Magnética/métodos , Tomografia por Emissão de Pósitrons/métodos , Cuidados Pré-Operatórios/métodos , Compostos Radiofarmacêuticos , Adulto , Feminino , Seguimentos , Humanos , Pessoa de Meia-Idade , Imagem Multimodal/métodos , Estadiamento de Neoplasias , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...